Description
The FC-100 provides 6 to 10 dB of feedback protection by analysing the incoming signal, detecting the presence of feedback and then notching out the feedback frequency.
The FC-100 relieves the sound engineer automatically. It works dynamically and eliminates a feedback signal before it can grow into a peak. Internally a discriminator circuit detects the presence of regenerative feedback and triggers the automatic equaliser to insert a notch where the feedback peak is coming up. This normally prevents other peaks from developing but if they do, the process is repeated at high speed, thus keeping feedback under control.
Technical Spec
In- and Outputs | transformer balanced |
max. Inputlevel | + 3 dB |
Gain (RS=200 Ohm, RL=2kOhm) | 0 dB |
Frequency Response | 20 Hz … 20 kHz, +/- 1,5 dB |
Feeback Cancellation | 6 … 10 dB |
Power Requirement | 30 … 48 V Phantom |
Current drain | ca. 8 mA |
External Power Supply | 9 … 20 V DC, 3,5 mm jack, tip + |
Housing | Aluminium Diecast |
Weight | 285 grams |
Dimensions | 112 x 60 x 32 mm |